Vlf Cable Tester
Vlf cable testers also known as vlf hipot testers are used to conduct vlf withstand tests.
Vlf cable tester. The vlf sine wave 34 kv is a compact robust and portable vlf sine wave test system for medium voltage cables. When vlf withstand testing cable the proper test voltage and time duration are critical for the success of the test. Vlf cable testing is the cutting edge technology for proof testing of fully operating medium voltage cables and the detection of faulty ones. Compared to traditional ac dc hipot testing vlf cable testing methods are able to more easily determine the high voltage field of.
Because the inherent capacitance of a power cable. Vlf testers are smaller and more practical than ac testers but output the same amount of power as a 50 hz mains device. From the above relationship when comparing vlf 0 1 hz to power frequency 60 hz there is a 600x lower power and current requirement when testing a cable at the same test voltage. The hva28td vlf high voltage test set is an ultra compact lightweight 0 1 hz vlf cable tester with integrated tan delta diagnostics.
Hva28 td vlf test set at a glance. The principal use of vlf is testing medium and high voltage shielded power cables. This combination of size and power makes very low frequency cable testing perfect for testing longer sections of cable and apparatus. As an ideal tool for routine cable testing.
This combination of size and power makes very low frequency cable testing perfect for testing longer sections of cable and apparatus. Once partial discharge is triggered in a defect under the test. Vlf systems are advantageous in that they can be manufactured to be small and lightweight. Vlf testing uses very low frequencies as part of an ac cable maintenance routine.
Vlf cable testing very low frequency is a technique for testing of medium and high voltage mv and hv cables. A long cable may have many microfarads of capacitance. Vlf testing uses very low frequencies as part of an ac cable maintenance routine. In the first step a go no go statement is sufficient.
Vlf cable testing makes use of ac voltages in a frequency range of 0 01. The device under test must withstand a vlf very low frequency ac voltage for a preset testing time without flashover. If a vlf test is too low in voltage and or too short in duration more harm than good may result. If a cable can t hold 2 3 times normal voltage it is not.
Vlf testers are smaller and more practical than ac testers but output the same amount of power as a 50 hz mains device. An ac voltage test is the best way to verify the ac integrity of a cable. The design optimized for rapid transportation and quick setup and the continuous duty cycle are two attributes that qualify the system. These tests are typically carried out on a frequency between 0 1 hz and 0 01 hz and operate off of a pass fail model.
With monitored withstand test mwt testing and diagnostics in compliance with ieee400. Perform the test as instructed to make best use of vlf technology.